Before updating to a newer version, please install the required mandatory versions in the correct order. If the update path, as illustrated below, is not followed, the eBOX will no longer work. Also, see below for ways to find out which version is currently installed.
Current VersionRequires version ≥2.0.34
BugfixRequires version ≥2.0.34
ProductionRequires version ≥2.0.34
OptionalRequires version ≥2.0.34
OptionalRequires VERSION ≥2.0.34
optionalRequires VERSION ≥2.0.34
optionalRequires VERSION ≥2.0.34
MandatoryRequires Version ≥1.3.38
MANDATORY
MANDATORYRequires VERSION ≥1.2.3
MANDATORYrequires VERSION ≥1.1.18
MANDATORY
Ways to find out which version is currently installed
option: OCPP BootNotification > firmwareVersion
option: Log into WebConfig and check System > System data > ACCU firmware version
option: Connect to your eBOX via eConfig app and click on the
How to install
A newer version can be installed via OCPP or WebConfig. For installation via WebConfig, log into WebConfig and go to ECU > Update to upload and install a file.
P5 controller: eTower, DUO (prod. date ≥2022), SOLO
Updating an eTower 200 can take up to 25 minutes!
Production DUO/SOLO/eTower
P4 controller: DUO (prod. date ≤2021), SOLO (prod. date ≤2020), CITO