Introduction
Hardware
About this document
This manual contains information about the connection to the local web interface (WebConfig) of Compleo eBOX professional. The purpose of this document is to describe how to properly configure and operate the advanced features of the WebConfig platform. This includes the implementation of important settings for smart charge regulations.
Please note
Make sure that the eBOX is set up and wired correctly. You will find a detailed assembly description in the user manual you received with your eBOX.
Preparations
To connect to the WebConfig of the eBOX, you need a working laptop and a LAN cable. Make sure you have the eBOX PUK ready to access the web interface. You can find the PUK on the last page of the user manual you received with your eBOX.
System overview and structure
Before mounting the eBOX, ensure the eCLICK is not connected to power. To access the eBOX web interface, the eBOX must be properly connected to the computer. For this to succeed, the system must be set up and wired as shown in Figure 1.
Take the eBOX and identify the connection points on its back. Connect the white ribbon data cable of the eBOX to the port "8 LAN 3 RJ45 (eBOX communication)".
Clicking the eBox into the eClick
After successfully connecting, the eBOX can be plugged into the eCLICK.
Please prepare the installation by fully pulling down the locking bracket and holding it firmly in this position. Now place the eBOX carefully on the eCLICK and push it firmly in the middle with the other hand until it stops Be careful not to exert excessive pressure on the circle LEDs.
Now release the bracket and let it lift automatically. Please hold the eBOX in place with one hand.
Please continue to hold the eBOX in place with one hand. Check the final position of the locking bracket, it must be fully raised. The enlarged detail view demonstrates the desired final position. The pin on the locking bracket must be exactly level with the triangle on the eBOX. If the bracket has not reached the desired final position, please push it further upwards to the desired final position.
Now the eBOX is mounted on the eCLICK and Power on the eCLICK circuit.
Initial access
You will need at least a laptop and a LAN cable. If the backend connection is to be made via a SIM card, now is a good time to insert it. Then connect the laptop to one of the Ethernet ports on the board in the charging station using a network cable.
Double click "Internet Protocol Version 4 (TCP/IPv4)".
Assign an IP address in the address range 172.16.0.x. Everything except .1 is OK because the charging station has this address. We recommend 172.16.0.99. Also, enter subnet mask 255.255.255.0. Then click on "OK" in both previously opened windows.
Login information for WebConfig:
To log in to WebConfig, you need the PUK of your eBOX. You can find it on the back of the supplied user manual. The default username is "admin".
User name: admin
Password: PUK
Smart Charge Point Regulation
OFF-Peak Charging
Please set the charger up as described below, to prevent charging during Peak hours.
Randomized delay
Every charging session and change in current output is subject to a randomized delay between 0 and 600 seconds (10 minutes) in the standard configuration.
Reason
Maintaining grid stability is a key Government policy objective for smart charging.
There is a risk that large numbers of charge points could start charging or change
their charging rate simultaneously, for example when recovering from a power
outage or in response to an external signal such as a ToU tariff. This could cause a
spike or sudden drop in demand and destabilize the grid.
Conclusion
To mitigate this, the Regulations set out requirements for randomized delay
functionality. Applying a randomized offset ensures grid stability by distributing
demand placed on the grid, gradually ramping up the electricity demand.
Default Config
A charge point must be configured to operate a default randomized delay of up to
600 seconds (10 minutes) at each charging instance (that is, any switch in the load that
is on, up, or down). The exact delay must:
be of a random duration between 0 to 600 seconds;
be conferred to the nearest second; and
be of a different duration for each charging instance.
The maximum randomized delay is configurable up to 1800 seconds (30 min)
There are two options for configuring this.
Text configuration
OCPP configuration
To change the maximum randomized delay via OCPP, use the change configuration command in your Backend to change the following parameter according to your desired duration in seconds:
ecu.uk_settings.max_charge_delay=600
Delay Override
The charge point is configured such that the random delay will not operate when:
an equivalent random delay has already been applied to the operation of the charge point with respect to this time
the owner or end-user who is not the owner has canceled the randomized delay by overriding it
Manual Delay Override
Security Log
Local Security Log
Security Log from Backend
In addition to the local download, another option is to download the diagnostics file from the OCPP Backend.
Please refer to your specific Backend provider on how to execute the OCPP standard command “GetDiagnostics”. The Log File will be included in the provided Diagnostics package.